1414 Distal Tibial Anterolateral Locking Plate L/R
Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency,
Payment: T/T, PayPal
Sichuan Chenanhui Tehnology Co., Ltd.is a supplier of orthopedic implants and orthopedic instruments and is engaged in selling them, owns its manufacturing factories in China, which sells and manufactures internal fixation implants Any inquiries we are happy to reply. Please choose Sichuan Chenanhui, and our services will definitely give you satisfaction.I : Core Application & Clinical Advantages of the 1414 Distal Tibial Plate
The implant is pre-contoured for the anterolateral ridge of the distal tibia, which is the surface a surgeon reaches most easily from the standard approach and the one where the plate has the least soft tissue to hide under. Each hole count is produced in a left and a right version under its own part number, so the plate arrives shaped for the side being operated on rather than being bent to fit. Lengths run from 104.3 mm at seven holes to 234.2 mm at seventeen holes in roughly 26 mm steps, at a constant 12.5 mm width and 4.2 mm thickness.
Table 1. Size range of the 1414 distal tibial plate, left and right types
|
Part No. |
Holes |
Length × Width × Thickness (mm) |
|
1414-A1007L / R |
7 |
104.3 × 12.5 × 4.2 |
|
1414-A1009L / R |
9 |
130.3 × 12.5 × 4.2 |
|
1414-A1011L / R |
11 |
156.3 × 12.5 × 4.2 |
|
1414-A1013L / R |
13 |
182.3 × 12.5 × 4.2 |
|
1414-A1015L / R |
15 |
208.2 × 12.5 × 4.2 |
|
1414-A1017L / R |
17 |
234.2 × 12.5 × 4.2 |
Two details do most of the work in theatre. The plate carries combination holes, so a screw can be used either to compress a fragment or to lock at a chosen angle from the same position, and the surgeon is not committed before the reduction is judged on image. The screw heads also sit nearly flush with the plate surface, which leaves a smoother bed for closure over the anterior ankle. Screws for this distal tibial anterolateral locking plate are the HC4.0 and HA4.0 locking pattern, driven with the drill sleeves, screwdrivers and depth gauges from our lower limb sets.
Core clinical merits
1.Handed anatomy instead of bench contouring. A left and a right plate exist for every hole count, so the contour is set before the incision and no time is lost bending a single design across the joint.
2.A fixed-angle raft over the metaphysis. Locked screws hold their angle in the small fragments and osteoporotic bone typical of this region, where a compression plate would rely on a cortex that may not be there.
3.Lengths that span only what needs spanning. Six sizes at about 26 mm steps let the plate stop short of the joint line, which is the cheapest way to protect ankle motion after a pilon-type injury.
4.A 4.2 mm section under thin cover. The plate is stiff enough to bridge a comminuted segment yet shallow enough that closure over the anterolateral border remains feasible without tension.
5.Limited-contact underside. Contact sits at the plate feet, so the periosteal vessels under the fracture are left alone; on the distal tibia that circulation is already the weakest link.
Choosing between implants here is a question of column and canal. A fracture that reaches the metaphysis and needs a raft under the articular block belongs with this plate. A mid-shaft pattern with an intact canal is shorter to treat with a nail, and our tibial interlocking nail system remains the default for that indication. Where the anterolateral column is intact but the medial side has failed, the mirror-image plate is not the answer and a medial design is. Dimensions for every size sit on the distal tibial locking plate product page, and the rest of the range is grouped under orthopedic trauma implants.
II : Full-cycle Postoperative Recovery, Limitations & Patient
Concerns
The recovery questions that arrive from distributors are remarkably consistent, so the usual clinical sequence for the distal tibial anterolateral locking plate is set out below. It describes common practice; the treating surgeon's protocol always governs.
1. Recovery & functional timeline
- Protected phase, weeks zero to two: the limb is kept in a splint or boot, ankle and toe movement is encouraged, and weight bearing is limited to touch-down.
- Progressive phase, weeks two to six: partial weight bearing begins under supervision, usually rising to half body weight by the end of the period once wound healing is confirmed.
- Strengthening phase, weeks six to sixteen: full weight bearing is built up as callus appears, and calf and ankle rehabilitation starts in earnest.
- Radiographic union is normally reported at three and a half to five months; removal of the distal tibial anterolateral locking plate is optional and, when requested, planned twelve to eighteen months after the index operation.
2.Main limitations & common complications
- Wound problems are the complication that matters most here: dehiscence, edge necrosis and superficial infection all occur where cover over the plate is thinnest, and they delay everything that follows.
- Anterolateral ankle stiffness and scar tethering are common and usually improve with early controlled motion rather than prolonged immobilisation.
- Screw loosening and delayed union are less frequent, and both are reduced by spanning the fracture with the shortest plate that still bridges it.
- Contraindication: heavily contaminated open fractures, active infection, cover that cannot be achieved over the implant, or a patient who cannot follow a protected weight-bearing plan.
3.Daily life guidance after surgery
- Desk work and short household walking return within a few weeks; running, jumping and impact sport are usually cleared at three to four months, once ankle dorsiflexion and calf strength are symmetrical enough to absorb load.
- Because the series runs from seven to seventeen holes, the smallest distal tibial anterolateral locking plate that spans the fracture can be selected, which limits dissection length and leaves more of the periosteum undisturbed.
Why Global Medical Distributors & Hospitals Choose the 1414 Series
✅ Factory-direct supply with no intermediary, and volume pricing across all six lengths, in both handed versions
✅ A balanced left and right range for the distal tibial anterolateral locking plate, seven to seventeen holes on one numbering system, with special lengths produced on request
✅ Medical pure titanium: corrosion resistant, high in toughness, and suitable for long-term implantation
✅ Dimensional and surface checks on every batch, with paperwork prepared for hospital tender submissions
✅ OEM cartons and a workable minimum order for trial stock; quality system records from an ISO 13485 and CE-MDR certified locking plate supplier, on request.
Get Wholesale Quotation for the 1414 Distal Tibial Plate
Email us: cah@medtechcah.com
WhatsApp / Call: +86 15008449628
For a price list, a left-right starter set or a sample plate, reach the trauma team through our contact page; pricing is given per size, per handed version or per complete set.
FAQ: Common Questions About the Maxillofacial Instrument Kit
Q1: Why an anterolateral plate rather than a medial one?
A: The anterolateral ridge is the surface with the least soft tissue and the most direct approach for the common fracture pattern, which is why the distal tibial anterolateral locking plate is built for that corridor. A medial plate is chosen when the medial column is the one that has failed or when the wound dictates a different corridor.
Q2: How is the hole count chosen?
A: Enough holes to place at least three screws in the distal fragment and three in the shaft, without crossing the joint line. In practice that means nine to thirteen holes for most cases, with seven for a short split and seventeen for a long comminuted bridge.
Q3: Do left and right plates have separate part numbers?
A: Yes. The L or R suffix is part of the number, so a purchase order should state the side; the two are not interchangeable and are not supplied as a pair unless requested.
Q4: Which screw pattern is required?
A: HC4.0 and HA4.0 locking screws. Cortical screws of the same pattern can be used through the compression side of a combination hole when interfragmentary compression is wanted.
Q5: What documentation ships with an order?
A: Batch-linked material certificates, dimensional inspection records and quality system documents for tender files; registration support is quoted separately by destination market.
Q6: Can trial orders mix lengths and sides?
A: Yes. Trial cartons may combine any of the six lengths in both handed versions of the distal tibial anterolateral locking plate, and OEM or private-label packaging is available for distributors building their own brand.