One-Third Tubular Locking Plate 1224 4-10 Holes Ti
Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency,
Payment: T/T, PayPal
Sichuan Chenanhui Tehnology Co., Ltd.is a supplier of orthopedic implants and orthopedic instruments and is engaged in selling them, owns its manufacturing factories in China, which sells and manufactures internal fixation implants Any inquiries we are happy to reply. Please choose Sichuan Chenanhui, and our services will definitely give you satisfaction.I : Core Application & Clinical Value of the Maxillofacial Instrument Kit
The one-third tubular locking plate, model 1224, is rolled into a shallow third-circle section and pre-contoured for the subcutaneous border of the ulna, which shortens intraoperative bending and keeps the implant from standing proud under thin skin. Seven lengths share one part-number sequence and each step adds 12 mm, so a single shelf covers a short oblique split as readily as a long comminuted segment.
Table 1. Size range of the 1224 one-third tubular locking plate
|
Part No. |
Holes |
Length × Width × Thickness (mm) |
|
1224-A1004 |
4 |
49 × 10 × 2.2 |
|
1224-A1005 |
5 |
61 × 10 × 2.2 |
|
1224-A1006 |
6 |
73 × 10 × 2.2 |
|
1224-A1007 |
7 |
85 × 10 × 2.2 |
|
1224-A1008 |
8 |
97 × 10 × 2.2 |
|
1224-A1009 |
9 |
109 × 10 × 2.2 |
|
1224-A1010 |
10 |
121 × 10 × 2.2 |
Width and thickness are held constant across the range at 10 mm and 2.2 mm. One bending template, one screwdriver and one screw family therefore serve every length, and a hospital does not need a second tray when it moves from a four-hole to a ten-hole case. The catalogue note is explicit: for ulna and radius fractures select the HC3.5 cortical screw, the small-fragment screw already stocked with our upper limb instrument sets.
Core clinical merits
1.Bone-following contour. The shallow third-circle curve tracks the subcutaneous ulnar border, so the plate needs little hand bending and leaves less dead space under thin skin.
2.Constant 10 × 2.2 mm section. The wall stays uniform from four to ten holes: light enough for the distal forearm, yet broad enough on the plate face for reliable screw purchase.
3..12 mm increments. Clinicians can choose the shortest implant that still bridges the fracture, which matters in comminuted patterns where over-spanning stiffens the construct for no clinical gain.
4..Pure titanium, passivated. Corrosion resistance and toughness suit long-term implantation, and the surface tolerates repeated trial-set handling before sterilisation.
One screw platform. Pairing with the HC3.5 cortical screw avoids a second screw line, an extra inventory code and a mismatch at the back table.
Selection is usually a comparison rather than a single choice. Against a plain tubular plate, threaded holes give angular stability that holds in a short or osteoporotic fragment, where compression alone may strip the cortex. Against a thicker reconstruction implant such as our limited contact dynamic compression plate, the low profile of the 1224 one-third tubular 5.plate leaves less metal under the wound, which counts on the ulnar border. The full size chart sits on the one-third tubular locking plates product page, and the wider range is listed under orthopedic trauma implants.
II : Full-cycle Postoperative Recovery, Limitations & Patient Concerns
Concerns
Forearm recovery questions repeat across markets, so the general clinical rules are summarised below.
1. Recovery & functional timeline
- Supervised finger, wrist and elbow motion starts within days of surgery; light grip and desk work usually resume at three to six weeks.
- Radiographic union of ulnar and radial shaft fractures is commonly seen at six to ten weeks, with forearm rotation approaching the uninjured side over three to four months.
- Removal is elective rather than routine; when a patient asks for it, the operation is scheduled twelve to eighteen months after the index procedure..
2. Main limitations & common complications
- Prominence over the subcutaneous ulnar border and scar tightness are the most frequent early complaints and normally settle within weeks.
- Screw back-out, soft tissue irritation and delayed union are uncommon; matching plate length to fragment length is the practical preventive step.
- Contraindication: heavily contaminated open fractures, active infection, or a soft tissue envelope that cannot cover the implant. In these situations the one-third tubular locking plate should be left in the tray and another fixation strategy chosen.
3. Daily life guidance after surgery
- Typing, writing and light household tasks return within a few weeks; heavy lifting and contact sport are usually cleared at eight to twelve weeks once grip strength is close to the uninjured side.
- Because lengths step by 12 mm, the clinician can pick the shortest one-third tubular locking plate that still spans the fracture, keeping the construct as compliant as the fixation goal allows.
Why Global Medical Distributors & Hospitals Choose the 1224 Series
✅ Factory-direct supply without intermediate traders, with tiered bulk pricing for tender volumes.
✅ Complete Q1202 configuration in every tray, plus spare bits and extractors shipped with each order.
✅ Stainless-steel working parts in an autoclavable tray that survives repeated reprocessing cycles.
✅ Routine dimensional and functional inspection, with documentation support for hospital procurement files.
✅ OEM packaging, logo marking and flexible minimum order quantities for trial orders.
Get Wholesale Quotation for the 1224 Locking Plate
Email us: cah@medtechcah.com
WhatsApp / Call: +86 15008449628
For a price list, a mixed-size trial carton or a sample of the 1224 locking plate, reach the trauma team through our contact page; quotations are given per size or per complete set.
FAQ : Common Questions About the 1224 One-Third Tubular Locking Plate
Q1: Which fracture patterns suit the 1224 plate?
A: Ulnar and radial shaft fractures with a short working length, including transverse splits, short oblique patterns and comminuted segments that need bridge fixation. The implant is contoured for the subcutaneous ulnar border; it is not a general-purpose forearm reconstruction plate.
Q2: Which screw should be ordered with it?
A: HC3.5 cortical screw is the catalogue pairing for ulna and radius fractures. If a hospital standardises on another 3.5 mm screw line, send the specification and we will confirm compatibility before quoting.
Q3: How many sizes should a distributor stock?
A: Six holes at 73 mm and eight holes at 97 mm cover most routine cases; four-hole and ten-hole lengths handle very short and very long segments. Mixed cartons across the series are accepted, and each length is invoiced separately.
Q4: What material is the plate made of?
A: The one-third tubular locking plate is machined from medical-grade pure titanium and passivated. It is corrosion resistant and ductile enough for bench contouring without losing fatigue strength.
Q5: Can a hospital place a trial order first?
A: Yes. Trial orders may mix sizes, and OEM packaging or private-label cartons are available; lead time depends on whether the carton is drawn from stock.
Q6: Is documentation available for tenders?
A: Test reports, material certificates and quality system documents are supplied with the quotation, and registration support follows the destination market.