banner

Medical Electric Mini Saw S1070/S2070 12500 cpm

Short Description:

Abstract: An osteotomy of a phalanx or a first metatarsal leaves almost no margin for a blade that grabs, heats or shatters. The medical electric mini saw from Sichuan Chenanhui Technology runs 0 to 12,500 cycles per minute on a sealed brushless motor, holds vibration low enough to protect the neurovascular bundles beside the cut, weighs 950 g and autoclaves at 151 degrees Celsius, 15 psi, with the battery removed.

Hand and foot surgery asks a power tool to do something a large-joint saw is never asked to do: cut a bone four millimetres wide, in a field crowded with digital nerves and tendons, without taking the soft tissue with it. Bunion correction, phalangeal osteotomy, metatarsal shortening and bone grafting all depend on a blade that advances under control and stops where the surgeon decides. This article sets out how the medical electric mini saw is built for that job, how blade choice and sterilization should be planned, and what a procurement team should compare before standardizing it.


Acceptance: OEM/ODM, Trade, Wholesale, Regional Agency,

Payment: T/T, PayPal

Sichuan Chenanhui Tehnology Co., Ltd.is a supplier of orthopedic implants and orthopedic instruments and is engaged in selling them, owns its manufacturing factories in China, which sells and manufactures internal fixation implants Any inquiries we are happy to reply. Please choose Sichuan Chenanhui, and our services will definitely give you satisfaction.

Product Detail

Product Tags

I : Core Application & Clinical Advantages of the Medical Electric Mini Saw

The handpiece carries a brushless, fully sealed high-output motor driving an oscillating blade at 0 to 12,500 cpm. The useful part of that range is the low end: a slow start lets the blade open a groove on a curved cortical surface before speed is brought up, and the top of the range carries the blade through the final millimetres without stalling. Because the motor is sealed, the unit can be sterilized by steam repeatedly without fluid reaching the rotor, which is where most powered handpieces in a busy department fail first.

The medical electric mini saw is supplied in two finishes, S1070 in black and S2070 in silver, and the rated values in Table 1 are the figures to quote against either model.

Table 1. Medical electric mini saw rated parameters

Parameter

Rated value

Where it matters in small-bone work

Saw frequency

0 to 12,500 cpm, infinitely variable Slow entry on curved cortex, clean through-cut

Motor

Brushless, fully sealed, high output Steam cycles without fluid reaching the rotor

Handpiece weight

950 g One-hand control through forefoot reconstruction

Noise level

75 dB or less Team communication in a small field

Temperature rise

25 degrees Celsius or less Limits thermal load on exposed soft tissue

Sterilisation

151 degrees Celsius at 15 psi, battery pack excluded Repeatable reprocessing between lists

Battery and charger

8 V, 1500 mAh; charger AC 100 to 240 V, 50 or 60 Hz Two packs cover a list; one charger fits any mains

Standard set

Main engine, 2 batteries, charger, isolation channel, 4 blades Enough consumables for the first cases

 

Core clinical merits:

  • Low vibration at the cut: oscillation is contained within the blade, so the soft tissue envelope and the adjacent neurovascular bundle are not shaken while the bone is divided, and the risk of a propagating crack in a small cortex drops with it.
  • Smooth, rapid osteotomy: 12,500 cpm under load gives a clean kerf in phalangeal and metatarsal bone, shortening the time a tourniquet has to stay up and reducing the thermal damage that comes from a slow, dragging blade.
  • 950 g balanced handpiece: the body sits in the palm through a forefoot reconstruction that runs for an hour or more, so the wrist is not fighting the tool while the other hand holds the toe in position.
  • Noise at or below 75 dB and temperature rise at or below 25 degrees Celsius: the team can talk through the case without raising voices, and the handpiece does not become uncomfortable in a long list.
  • Fully autoclavable handpiece, battery pack excluded: 151 degrees Celsius at 15 psi with the battery removed, and a sealed motor that keeps the hermetic barrier intact between patients.

The medical electric mini saw is a small-bone instrument and should be bought as one. Dividing a femoral neck or opening a knee is work for a high-level reciprocating saw, and a unit that also needs drilling in the same tray is better served by the micro multifunctional drill and saw system, which shares one motor across both functions. Blades are consumables, and our orthopaedic saw blade range carries the replacement sizes so a department is never waiting on a single worn blade. Fixation of the osteotomy itself, including phalangeal locking plates, sits in the trauma line, and the full handpiece range is grouped in our orthopaedic power system range by bone size.

Mini Saw
Mini Saw (black)

II : Blade Planning, Sterilisation & Tender Comparison

1. Blade selection and cut planning

  • A narrow fine-tooth blade suits a phalangeal osteotomy where the bone is a few millimetres across, while a wider blade is used for metatarsal work where the cut is longer and the approach allows more room.
  • Four blades ship with each set, which covers the first cases without a separate consumable order; a department that runs regular bunion lists should hold a spare of each width it uses.
  • A blade is changed when the teeth dull rather than when it fails, because a dull blade heats the bone and needs more pressure, and pressure is what makes a blade walk off the planned line.

2. Sterilisation and battery handling

  • The handpiece is autoclaved at 151 degrees Celsius and 15 psi with the battery pack removed; the sealed motor is what allows that cycle to be repeated across the working week.
  • Batteries are wiped and charged outside the sterile field, and two 8 V, 1500 mAh packs ship with every set so one can charge while the other runs a list.
  • The isolation channel and the chuck are counted with the tray before packing, since a missing component stops a case as effectively as a blunt blade.

3. What to compare before standardizing

  • Ask for the cpm figure under load and the vibration figure as measured values, because a saw that only reaches its rated speed unloaded will bog down in cortical bone.
  • Test the handpiece in a wet lab on a sawbone phalanx, which shows blade control and heat generation faster than any specification sheet.
  • Check the sterilization temperature and pressure, and confirm in writing that the battery of the medical electric mini saw is excluded from the cycle.
  • Confirm blade availability and the local service route, because a saw without consumables in country is a saw that sits in the cupboard.

Why Global Medical Distributors & Hospitals Choose Our Medical Electric Mini Saw

✅ Factory-direct supply without intermediate traders, with tiered pricing for department and tender volumes.
✅ Complete set in every carton: main engine, two batteries, fast pulse charger, isolation channel and four saw blades.
✅ Sealed brushless motor and a handpiece autoclavable at 151 degrees Celsius, 15 psi, built for repeated reprocessing.
✅ Rated parameters published as figures rather than adjectives, so procurement can compare against imported sets line by line.
✅ Custom device colour and packaging for OEM and distributor branding, with flexible minimum order quantities.

Get Your Wholesale Quotation for the Medical Electric Mini Saw

Email us: cah@medtechcah.com

WhatsApp/Call: +86 15008449628

Send the osteotomy types your unit performs and the number of handpieces you plan to hold, and our power instrument team replies with a configuration sheet, blade list and unit pricing within one working day.

FAQ: Common Questions About the Medical Electric Mini Saw

Q1: Which procedures is this saw intended for?

A: Small-bone osteotomy of the hand and foot, including phalangeal osteotomy, bunion correction of the first metatarsal, metatarsal shortening, bone grafting and forefoot reconstructive work where the cut has to stay inside a narrow field.

Q2: Why does the speed range start at zero?

A: A slow start lets the surgeon open a groove on a curved cortex before the blade reaches full speed, and the variable range up to 12,500 cpm keeps the cut under control from the first millimetre to the last.

Q3: How is the handpiece sterilized?

A: By steam at 151 degrees Celsius and 15 psi with the battery pack removed. The sealed brushless motor keeps liquid out of the rotor across repeated cycles, which is what maintains the barrier between patients.

Q4: What is included in a standard set?

A: One main engine in the ordered finish, either S1070 black or S2070 silver; two 8 V, 1500 mAh batteries; one fast pulse charger rated AC 100 to 240 V at 50 or 60 Hz; one isolation channel; four saw blades; one instruction manual and outer packaging.

Q5: Are blades available separately?

A: Yes. Replacement blades in the widths used for phalangeal and metatarsal work are supplied separately, and we recommend holding one spare of each width in the department.

Q6: Can distributors order OEM colours and packaging?

A: Yes. Device colour and outer packaging can be customized for distributor branding, and trial orders can start below bulk volume; a configuration sheet and unit pricing are provided on request.


Note: technical figures here summarize the manufacturer specification for the instrument described, are intended for healthcare professionals, and do not replace surgical judgment, local protocol or the instructions for use.

Video

  • Mini Saw (black)
  • Mini Saw

  • Previous:
  • Next:

  • Write your message here and send it to us